DWC Pipe Joining with a Join Tracker
Author: Evan Cornelius • 26 September 2024 • 2 Minute Read • Article
DWC pipe joining using a Join Tracker is a common method for creating a strong, secure connection between double-wall corrugated (DWC) pipes. The following are the general steps for joining DWC pipes with a Join Tracker:
1. Preparing Tools and Materials:
-
- DWC pipes to be joined.
- Join Tracker (pipe extraction tool).
- Joint rubber (gasket/rubber ring).
- Special pipe lubricant.
- Supporting tools such as wrenches and brackets.
2. Preparing the Pipes:
-
- Make sure both ends of the pipes to be joined are free of dirt, dust and other particles.
- Check the condition of the pipes to make sure there is no damage that could affect the joint.
3. Fitting the Rubber Gasket:
-
- Fit the rubber gasket to the end of the first pipe. Check that the gasket is seated correctly and is not bent.
4. Lubrication:
-
- Apply lubricant to the rubber gasket and the end of the second pipe to make joining easier and reduce friction.
5. Installing the Join Tracker:
-
- Attach the Join Tracker to the pipes being connected. Make sure it is fitted firmly and securely.
- A Join Tracker generally has a pulling mechanism that draws the second pipe into the first pipe, which is fitted with a rubber gasket.
6. DWC Pipe Joining:
-
- Operate the Join Tracker slowly to pull the second pipe into the rubber gasket on the first pipe.
- Pull slowly and continuously until the second pipe is fully inserted into the first pipe and the rubber gasket is in the correct position.
7. Inspection:
-
- After joining, inspect the joint again to make sure there are no gaps or leaks.
- Check that the rubber gasket is in the correct position and is not bent.
8. Securing the Joint:
-
- If necessary, place a clamp or cable tie around the joint so it remains secure and does not come apart easily.
- Make sure the joint is completely secure before carefully removing the Join Tracker.
This joining method using a Join Tracker is highly effective, especially for projects that require large-diameter pipes or strong permanent joints. Always follow safety instructions during the joining process to avoid injury or damage to the pipes.
Tagged #corrugated pipe
#hdpe piping